Studies on Point-Contact Germanium Detector Bulk-Surface Discrimination at Near-Threshold Energies using Pulser-Generated Pulse Shapes
Jia-Shian Wang1*, Hau-Bin Li1, Manoj K. Singh1, Henry T. Wong1
1Institute of Physics, Academia Sinica, Taipei, Taiwan
* Presenter:Jia-Shian Wang, email:jswang2022@gate.sinica.edu.tw
The p-type point-contact Germanium detectors (PPCGe) [1] have been widely adopted in searches of low energy events such as neutrinos and dark matter, e.g. TEXONO [2], CoGeNT [3] and CDEX-1 [4], etc. This is due to their enhanced capabilities of background rejection, sensitivity at energies as low as the sub-keV range and particularly fine energy resolution. Nonetheless, the PPCGe is subject to irregular behaviour caused by surface effects for events near the passivated surface. The signal pulses of such events will exhibit slower rise time and lower amplitude compared to that of proper signals originating from the detector bulk volume. Surface events can, therefore, be distinguished from bulk events via simple pulse-rise-time comparison. In the sub-keV region, however, the rise time spectra of bulk and surface pulses overlap, and become hardly distinguishable. Thus, it is vital to develop techniques that improve the measurements of bulk-surface leakage at lower energies.

In previous studies [5, 6], the bulk-surface leakage was measured mainly using radioactive sources. The main limitation of the approach is that only sources of well-known spectral shapes can be used for calibration. Alternatively, one can produce artificial pulses imitating different signal pulses by using an external pulse generator (pulser). In this study, we will demonstrate that pulser-generated pulses can indeed be rendered to mimic both bulk and surface pulses. By confirming that the pulse shapes of pulser-generated pulses and signal pulses match at higher energies, the pulser-generated pulses of reduced amplitude should then, in principle, be representative of the low energy signal pulses. In this case, the pulser can be employed as a controlled input that is able to reproduce pulses of both types at arbitrary energy. Our aim is then to develop an effective pulse shape discrimination technique based on these pulser-generated pulses to improve the bulk-surface leakage measurement at near-threshold energies.


Reference:
[1] A. K. Soma et. al., Characterization and Performance of Germanium Detectors with sub-keV Sensitivities for Neutrino and Dark Matter Experiments, Nucl. Instr. Meth. Phys. Res. A 836, 67-82 (2016).
[2] H. B. Li et. al., Limits on Spin-Independent Couplings of WIMP Dark Matter with a p-Type Point-Contact Germanium Detector, Phys. Rev. Lett. 110, 261301 (2013).
[3] C. E. Aalseth et. al., Results from a Search for Light-Mass Dark Matter with a p-Type Point Contact Germanium Detector, Phys. Rev. Lett. 106, 131301 (2011).
[4] W. Zhao et. al., First Results on Low-Mass WIMPs from the CDEX-1 Experiment at the China Jinping Underground Laboratory, Phys. Rev. D 88, 052004 (2013).
[5] H. B. Li et. al., Differentiation of Bulk and Surface Events in p-type Point-Contact Germanium Detectors for Light WIMP Searches, Astropart. Phys. 56, 1-8 (2014).
[6] L. T. Yang et. al., Bulk and Surface Event Identification in p-type Germanium Detectors, Nucl. Instr. Meth. Phys. Res. A 886, 13-23 (2018).


Keywords: Germanium Detector, Pulse Shape Discrimination, Ultra-Low Energy